interSeptor Sensors
|
interSeptor sensors are available for a wide variety of applications. Sensors are
available for monitoring temperature and humidity, water leaks, smoke, door
access, utility power, and other open/close contact or low voltage sensing.
|
|
|
|
Each interSeptor has two temperature/humidity sensor ports (EMD-1 & EMD-2),
and each interSeptor is provided with one combination temperature/humidity sensor.
This sensor has provisions on it for connecting two additional contact sensors.
|
interSeptor back panel pictorial
|
interSeptor plugs directly into your 10/100Mbps network. The included temp/humidity
sensor (EMD) comes with a 2 meter cat5 cable for connecting to one of the two EMD ports
on the interSeptor back panel. You may then piggy-back up to 2 additional water,
smoke, security or any dry contact sensors to the EMD. By adding another temp/humidity
sensor, you may then add two more contact sensors for a total capacity of 6 monitored
sensors.
You may substitute your own cat5 straight-thru cable to connect the EMDs.
|
|
|
|
Sensor Links
|
|
Click on an optional interSeptor sensor:
All sensors are available in both short and long cable lengths.
|
Temperature and Humidity Sensor
High and low warning and critical temperature and humidity thresholds can be configured
in the interSeptor to ensure alarms are raised when room or rack conditions are
abnormal. The hysteresis configuration facility ensures that alarms are not continually
triggered when levels are ‘floating’ around the configured thresholds.
|
|
|
|
|
|
|
Water Leak Sensor
The interSeptor water leak sensor is supplied with 3m or 18m of leak detection cable.
The cable can be run under air conditioning units, in ceiling voids, under raised
floors, under pipes, and around room perimeters to provide a comprehensive, easy-to-install,
leak detection facility.
|
|
|
|
|
|
|
|
|
Smoke Sensor
The unique sensor connectivity design of the interSeptor facilitates installation
and monitoring of the smoke detector, especially on ceilings. The cable connection
need only be run from the temperature/humidity sensor which will typically already
be installed at an elevated level.
|
|
|
|
|
|
|
|
|
Security Sensor
The security sensor option is a magnetic reed contact sensor, ideal for monitoring
rack or room door access.
|
|
|
|
|
|
|
Power Sensor
The power sensor will detect the presence or absence of utility power.
|
|
|
|
|
|
|
Universal (Dry Contact)
The Universal sensor is an interface cable that can be connected to any device offering
an open or closed or high/low output. interSeptor can monitor this output for changes
in state and alarm accordingly. The Universal sensor can be connected to equipment
such as generators, air conditioning units, printers, UPS, security systems, fire
alarm systems, etc.
|
|
|
|
|
|
|
|
|
|